One-stop Electronic Manufacturing Services, help you easily achieve your electronic products from PCB & PCBA

AS6081 test standard

Testing and Inspection

Minimum sample size

level

 

 

The batch quantity is not less than 200 pieces

Batch quantity: 1-199 pieces (see Note 1)

 

Necessary test

 

 

A level

Contract text and encapsulation

 

 

A1

Contract Text and Packaging inspection (4.2.6.4.1) (non-destructive)

All

All

 

Inspection of appearance

 

 

A2

a. Overall (4.2.6.4.2.1) (non-destructive)

All

All

 

b. Details (4.2.6.4.2.2) (non-destructive)

122pieces

122pieces or all(Batch quantity less than 122 pieces)

 

Retyping and refurbishing (lossy)

See Note 2

See Note 2

A3

Solvent test for typing (4.2.6.4.3A) (lossy)

3pieces

3pieces

 

Solvent test for refurbishment (4.2.6.4.3B) (lossy)

3pieces

3pieces

 

X ray detection

 

 

A4

X-ray detection (4.2.6.4.4) (non-destructive)

45 pieces

45 pieces or all (batch quantity less than 45 pieces)

 

Lead detection (XRF or EDS/EDX)

See Note3

See Note3

A5

XRF (Lossless) or EDS/EDX (Lossy) (4.2.6.4.5) (Annex C.1)

3pieces

3pieces

 

Open cover internal analysis (lossy)

See Note6

See Note6

A6

Open cover (4.2.6.4.6) (lossy)

3pieces

3pieces

 

Additional testing (agreed by both Company and customer)

 

 

 

Retyping and refurbishing (lossy)

See Note 2

See Note 2

A3 option

Scanning electron microscopy (4.2.6.4.3C) (lossy)

3pieces

3pieces

 

Surface quantitative analysis (4.2.6.4.3D) (non-destructive)

5pieces

5pieces

 

Test of heat

 

 

B level

Thermal cycle Test (Annex C.2)

All

All

 

Test of electrical properties

 

 

C level

Electrical Testing (Annex C.3)

116pieces

All

 

Aging test

 

 

D level

Burn-in testing (before and after testing) (Annex C.4)

45pieces

45 pieces or all (batch quantity less than 45 pieces)

 

Confirmation of tightness (minimum leak rate and maximum leak rate)

 

 

E level

Confirmation of tightness (minimum and maximum leakage rates) (Annex C.5)

All

All

 

Acoustic scanning test

 

 

F level

Acoustic scanning microscope (Annex C.6)

By rule

By rule

 

Other

 

 

G level

Other tests and inspections

By rule

By rule

 

Notes: 

1. For batches of less than 10 pieces, Cognizant Engineers may, in their sole discretion, reduce the sample size for the "lossy" test to 1 piece, subject to the quality of the test and the consent of the Customer. 

2. Samples for retyping and refurbishing testing may be selected from the batch for "Appearance Testing - Detail Testing". 

3. Lead test samples can be selected from the batch for "Appearance Test - Detail Test". 

4. Open cover test samples can be selected from the batch undergoing "Retyping and Refurbishing Test".